德国倍加福KFD、KCD安全栅;传感器,编码器,常规型号库存备货进口工控备件
-
≥ 1个¥1000.00
曹女士 工作8
曹女士 工作8
曹女士 工作8
德国倍加福KFD、KCD安全栅;传感器,编码器,常规型号库存备货 进口工控备件
德国倍加福KFD、KCD安全栅;传感器,编码器,常规型号库存备货 进口工控备件
德国倍加福KFD、KCD安全栅;传感器,编码器,常规型号库存备货 进口工控备件
KFD2-GU-1 KFD0-CS-EX1.51P KFD0-CS-EX1.54 KFD0-RO-EX2 KFD0-SCS-EX1.55 KFD0-SD2-EX1.10100 KFD0-SD2-EX1.1045 KFD0-SD2-EX2.1045 KFD0-TR-EX1 KFD2-CD-1.32 KFD2-CD2-EX2 KFD2-CD-EX1.32 KFD2-CRG2-1.D KFD2-CRG2-EX1.D KFD2-DWB-EX1.D KFD2-EB2-R4A.B KFD2-PT2-EX1-5 KFD2-SCD2-1.LK KFD2-SCD2-EX2.LK KFD2-SCD-EX1.LK KFD2-SL2-EX1 KFD2-SL2-EX2.B KFD2-SL2-EX1.B KFD2-SOT2-EX2 KFD2-SR2-EX1.W KFD2-SR2-EX2.W KFD2-SRA-EX4 KFD2-ST2-EX2 KFD2-STC4-1 KFD2-STC4-1.20 KFD2-STC4-2 KFD2-STC4-EX1 KFD2-STC4-EX1-Y122583 KFD2-UFC-1.D KFD2-UFC-EX1.D KFD2-USC-1.D KFD2-UT2-1 KFD2-UT2-2 KFD2-UT2-EX1 KFD2-UT2-EX1-1 KFD2-UT2-EX2 KFD2-UT2-EX2-1 KFD2-VR2-EX1.50M KFD2-VR4-EX1.26 KFD2-VR-EX1.500M KFDO-CC-EX1 KFDO-SD2-EX1.10100 KFD2-STC4-EX1.20 KFD2-VR4-EX1.26 KFD2-UFC-EX1.D KFD2-STC4-EX1.20 KFA6-SOT2-EX2 KFA6-SR2-EX1.W KFA6-SR2-EX2.W KFA6-DWB-EX1.D KFU8-FSSP-1.D KFU8-UFC-1.D KFU8-UFC-EX1.D KFU8-FSSP-1.D KCD2-RR-EX1 KCD2-SCD-1 KCD2-SCD-EX1 KCD2-SR-EX1.LB KCD2-SR-EX2 KCD2-STC-EX1.2O KCD2-UT2-EX1 KCD2-STC-EX1 KCD2-SCD-EX1
10-11331_R-1000 10-11631_A-1024 14-14361-1024 IC-KP2-2HB6-V15B
AVM58I-011K1AHBN-1212 AVM58N-011K1R0GN-1213 AVM58N-011K1R0GN-1213 AVS58N-011AARHGN-0013 AVS58N-011K1R0GN-0013 DVM58N-011AGR0BN-1213 DVM58N-011AGR0BN-1213 FVM58N-011K2R3BN-1213 FVM58N-032K2R3BN-1213 FVM58N-032K2R3GN-1213
PVM58I-011AGR0BN-1213 PVM58I-011AGROBN-1213 PVM58N-011AGR0BN-1213 PVS58I-
菲尼克斯
quint-ps/3AC/24DC/20 quint-ps/3AC/24DC/20
quint-ps/3AC/24DC/40 quint-ups/ 24DC/ 24DC/20
quint-ups/ 24DC/ 24DC/20 quint-ups/ 24DC/ 24DC/20
quint-ups/ 24DC/ 24DC/20 quint-ups/ 24DC/24DC20
quint-ups/ 24DC/ 24DC/20 2320 quint-ups/ 24DC/ 24DC/40
quint-ps-3x400-500ac/24DC/20 Quint-PS-3X4005008c/24Dc/40
quint-ps/1AC/24DC/20 quint-ps/ 1AC/24DC/20
Quint-ps/1AC/24DC/40quint-ps/1AC/24DC/40
quint-ps/1AC/24DC/ quint-ps/3AC/24DC
quint-ps/1AC/24D0 quint-ps/1AC /24DC/1General specifications
Signal type Digital Input
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2
Supply
Connection terminals 23, 24
Rated voltage Ur 20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz
Power dissipation/power consumption ≤ 2 W ; 2.5 VA / 2.2 W ; 3 VA
Interface
Programming interface programming socket
Input
Connection side field side
Connection Input I: intrinsically safe: terminals 1+, 3-
Input II: non-intrinsically safe: terminals 13+, 14-
Input I sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact
Pulse duration > 50 µs
Input frequency 0.001 ... 5000 Hz
Line fault detection breakage I ≤ 0.15 mA; short-circuit I > 6.5 mA
Input II startup override: 1 ... 1000 s, adjustable in steps of 1 s
Active/Passive I > 4 mA (for min. 100 ms) / I < 1.5 mA
Open circuit voltage/short-circuit
current
18 V / 5 mA
Output
Connection side control side
Connection output I: terminals 10, 11, 12
output II: terminals 16, 17, 18
outout III: terminasl 19+, 20-
output IV: terminals 8+, 7-
Output I, II signal, relay
Contact loading 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A
Mechanical life 5 x 107 switching cycles
Energized/De-energized delay approx. 20 ms / approx. 20 ms
Output III electronic output, passive
Contact loading 40 V DC
Signal level 1-signal: (L+) - 2.5 V (50 mA, short-circuit/overload proof)
0-signal: switched off (off-state current ≤ 10 µA)
Output IV analog
Current range 0 ... 20 mA or 4 ... 20 mA
Open loop voltage ≤ 24 V DC
Load ≤ 650 Ω
Fault signal downscale I ≤ 3.6 mA , upscale ≥ 21.5 mA (acc. NAMUR NE43)
Transfer characteristics
Input I
Measurement range 0.001 ... 5000 Hz
Resolution 0.1 % of the measurement value , ≥ 0.001 Hz
Accuracy 0.1 % of the measurement value , > 0.001 Hz
Measuring time < 100 ms
Influence of ambient temperature 0.003 %/K (30 ppm)
Output I, II
Response delay ≤ 200 ms
Output IV
Resolution < 10 µA
Accuracy < 20 µA
Influence of ambient temperature 0.005 %/K (50 ppm)
Galvanic isolation
Input I/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Mutual output I, II, III reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output III/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output III/start-up override basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output III/IV basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output IV/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Start-up override/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Interface/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Interface/output III basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Release date 2018-05-08 08:06 Date of issue 2018-05-08 231197_eng.xml
Technical data KFU8-UFC-Ex1.D
3
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
Pepperl+Fuchs Group USA: +1 330 486 0002 Singapore: +65 6779 9091 Germany: +49 621 776 2222
pa-info@ pa-info@ pa-info@
Indicators/settings
Display elements LEDs , display
Control elements Control panel
Configuration via operating buttons
via PACTware
Labeling space for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Low voltage
Directive 2014/35/EU EN 61010-1:2010
Conformity
Electromagnetic compatibility NE 21:2006
Degree of protection IEC 60529:2001
Input EN 60947-5-6:2000
Ambient conditions
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protection IP20
Connection screw terminals
Mass 300 g
Dimensions 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection
with hazardous areas
EU-Type Examination Certificate TÜV 99 ATEX 1471
Marking ¬ II (1)G [Ex ia Ga] IIC
¬ II (1)D [Ex ia Da] IIIC
¬ I (M1) [Ex ia Ma] I
Supply
Maximum safe voltage Um 253 V AC / 125 V DC (Attention! Um is no rated voltage.)
Input I terminals 1+, 3-: Ex ia
Voltage Uo 10.1 V
Current Io 13.5 mA
Power Po 34 mW (linear characteristic)
Input II terminals 13+, 14- non-intrinsically safe
Maximum safe voltage Um 40 V (Attention! The rated voltage can be lower.)
Output I, II terminals 10, 11, 12; 16, 17, 18 non-intrinsically safe
Maximum safe voltage Um 253 V (Attention! The rated voltage can be lower.)
Contact loading 253 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load (TÜV 99 ATEX 1471)
Output III terminals 19+, 20- non-intrinsically safe
Maximum safe voltage Um Um 40 V (Attention! Um is no rated voltage.)
Output IV terminals 8+, 7- non-intrinsically safe
Maximum safe voltage Um 40 V DC (Attention! Um is no rated voltage.)
Interface RS 232
Maximum safe voltage Um 40 V (Attention! Um is no rated voltage.)
Galvanic isolation
Input I/other circuits safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012
International approvals
FM approval
Control drawing 16-538FM-12
IECEx approval IECEx TUN 04.0007
Approved for [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
General information
Supplementary information Observe the certificates, declarations of conformity, instruction 0
quint-ps/1AC/24DC/20 quint-ps/1AC/48DC/5
quint-ps/24DC/24DC/5
Mini-Ps-100240c/10-15C/2 mini-ps-100-240ac/24DC/1
mini-ps-100-240AC/24DC/1.3 mini-ps-100-240AC/24DC/1.3
mini-ps-100-240ac/24DC/1.5/EX miwt-ps-100240c/24c/1.5/EX
mini-ps-100-240ac/24DC/4 mini-ps-100-2409C/24DC/4
mini-ps-100-240ac/2X15DC/1 mini-PS-100-240AC/2X15DC/1
mini-ps100-2408C/2x15C/1 mini-ps-100-240ac/2*15DC/1
PLC- REL-
FL SWITCH SFN 4TX/FX