95瓷转轴
-
面议
Porcelain insulators are suitable for use under working conditions where the working temperature does not exceed 250 ℃, the DC working voltage is 72KV to 100KV, and the altitude of the installation site does not exceed 1000m. The torsional failure load shall not be less than 1000N. m.
Porcelain insulators shall strictly comply with GB/T772-2005 Technical Conditions for High Voltage Insulator Porcelain Components and B/T6746. Manufacture of Porcelain Insulators for Electrostatic Precipitators (3-1993). The surface of porcelain pieces shall be painted with white or brown glaze.
Note: Porcelain parts with different porcelain grades can withstand temperatures ≤ 250 ℃, ≤ 350 ℃, ≤ 500 ℃, and be used in environments with a working voltage of 72-120KV